Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 311
Filtrar
1.
Polymers (Basel) ; 16(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38611235

RESUMO

The general requirement of replacing petroleum-derived plastics with renewable resources is particularly challenging for new technologies such as the additive manufacturing of photocurable resins. In this work, the influence of mono- and bifunctional reactive diluents on the printability and performance of resins based on acrylated epoxidized soybean oil (AESO) was explored. Polyethylene glycol di(meth)acrylates of different molecular weights were selected as diluents based on the viscosity and mechanical properties of their binary mixtures with AESO. Ternary mixtures containing 60% AESO, polyethylene glycol diacrylate (PEGDA) and polyethyleneglycol dimethacrylate (PEG200DMA) further improved the mechanical properties, water resistance and printability of the resin. Specifically, the terpolymer AESO/PEG575/PEG200DMA 60/20/20 (wt.%) improved the modulus (16% increase), tensile strength (63% increase) and %deformation at the break (21% increase), with respect to pure AESO. The enhancement of the printability provided by the reactive diluents was proven by Jacobs working curves and the improved accuracy of printed patterns. The proposed formulation, with a biorenewable carbon content of 67%, can be used as the matrix of innovative resins with unrestricted applicability in the electronics and biomedical fields. However, much effort must be done to increase the array of bio-based raw materials.

2.
Cureus ; 16(3): e55804, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38586635

RESUMO

STATEMENT OF PROBLEM: New-generation denture base materials are used successfully in denture fabrication; however, the effect of saliva pH change on the color stability of materials is unknown. PURPOSE: The purpose of this in vitro study is to evaluate the color stability of new-generation denture base materials after immersion in artificial saliva with different pH values (3,7,14). MATERIAL AND METHODS: Disc-shaped samples (Ø 10 mm x 2 mm) were prepared from three different denture base materials (1 pre-polymerized polymethylmethacrylate [PMMA], 1 graphene-reinforced PMMA, and heat-cure polymethyl methacrylate resin) (n=10). After polishing, color coordinates were measured using a PCE-CSM 5 colorimeter programmed in the CIE system (L* a* b*). The samples were kept in artificial saliva at different pH values and 37°C for 21 days. At the end of 21 days, color coordinates were measured again. The suitability of the measurements for a normal distribution was examined with the Kolmogro-Smirnov test. Whether color measurements obtained at different pH levels differed according to groups was examined with the Kruskal-Wallis test. The correlation between the CIEDE2000 and CIELab color difference formulas was examined by correlation analysis. RESULTS: The highest color difference occurred in heat-cure samples at pH 3 (p<0.001). The color difference at different pH values was least observed in pre-polymerized PMMA samples. Significant color differences occurred in the graphene-reinforced pre-polymerized PMMA group at pH 7 (p<0.001). CONCLUSIONS: It was observed that color differences occurred in all groups. Dentures made of new-generation CAD/CAM PMMA, which are less exposed to color differences, can be recommended for elderly patients with systemic diseases who are frequently exposed to pH changes in the oral cavity. CLINICAL IMPLICATIONS: Color differences on denture surfaces over time negatively affect aesthetics. Since pH changes cause changes on the prosthesis surface, it may be recommended for these patients to fabricate dentures from new-generation CAD/CAM PMMA resins, which are less deformable.

3.
J Pharm Bioallied Sci ; 16(Suppl 1): S427-S430, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595483

RESUMO

Background: Surface roughness and hardness are key factors that influence the clinical performance and durability of denture teeth. Understanding variations in these properties among different denture teeth materials can assist in selecting the most suitable materials for optimal patient outcomes. This study aimed to investigate the surface roughness and hardness of four commonly used denture teeth materials: acrylic resin, composite resin, porcelain, and nanohybrid composite. Materials and Methods: Ten specimens were prepared for each denture teeth material, resulting in a total of 40 specimens. Surface roughness was assessed using a profilometer, and measurements were recorded in micrometers (µm). Hardness was determined using a Vickers hardness tester, and results were expressed as Vickers hardness numbers (VHN). The surface roughness and hardness data were analyzed using appropriate statistical tests (e.g., analysis of variance), with significance set at P < 0.05. Results: The results revealed significant differences in both surface roughness and hardness among the different denture teeth materials (P < 0.05). Acrylic resin exhibited the highest surface roughness (mean ± standard deviation: 3.45 ± 0.78 µm) and the lowest hardness (mean ± standard deviation: 45.6 ± 2.3 VHN). Composite resin demonstrated intermediate values of surface roughness (mean ± standard deviation: 1.87 ± 0.54 µm) and hardness (mean ± standard deviation: 65.2 ± 3.9 VHN). Porcelain demonstrated the smoothest surface (mean ± standard deviation: 0.94 ± 0.28 µm) and the highest hardness (mean ± standard deviation: 78.5 ± 4.1 VHN). Nanohybrid composite displayed surface roughness and hardness values similar to composite resin. Conclusion: This study demonstrated significant variations in surface roughness and hardness among the different denture teeth materials evaluated. Acrylic resin exhibited the roughest surface and lowest hardness, while porcelain demonstrated the smoothest surface and highest hardness. Composite resin and nanohybrid composite exhibited intermediate values. These findings provide valuable insights for prosthodontic practitioners in selecting denture teeth materials based on specific clinical requirements, aiming to achieve optimal aesthetics, reduced plaque accumulation, and improved wear resistance.

4.
J Pharm Bioallied Sci ; 16(Suppl 1): S681-S683, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595564

RESUMO

Background: Recent advancements in three-dimensional (3D) printing have introduced novel materials for removable partial dentures (RPD) base fabrication, promising improved mechanical properties, and biocompatibility. Materials and Methods: In this study, three different RPD base materials were evaluated: conventional heat-cured acrylic resin (Control), biocompatible 3D-printed resin (Test Group A), and a novel nanocomposite 3D-printed resin (Test Group B). A total of 30 standardized RPD base specimens (n = 10 per group) were fabricated according to established protocols. Microstructural analysis was performed using scanning electron microscopy (SEM), and the mechanical properties, including flexural strength and modulus, were determined using a universal testing machine. Results: Microstructural analysis revealed distinct differences among the materials. SEM images showed a well-defined and homogeneous microstructure in Test Group B, while Test Group A exhibited fewer voids compared to the Control group. Mechanical testing results indicated that Test Group B had the highest flexural strength (120 ± 5 MPa), followed by Test Group A (90 ± 4 MPa), and the Control group (75 ± 3 MPa). Similarly, Test Group B demonstrated the highest flexural modulus (3.5 ± 0.2 GPa), followed by Test Group A (2.8 ± 0.1 GPa), and the Control group (2.1 ± 0.1 GPa). Conclusion: These findings suggest that 3D-printed RPD base materials, particularly nanocomposite resins, hold promise for improving the overall quality and durability of removable partial dentures.

5.
BMC Oral Health ; 24(1): 303, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38439020

RESUMO

BACKGROUND: The present systematic review and meta-analysis investigated the available evidence about the adherence of Candida Albicans to the digitally-fabricated acrylic resins (both milled and 3D-printed) compared to the conventional heat-polymerized acrylic resins. METHODS: This study followed the guidelines of the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA). A comprehensive search of online databases/search tools (Web of Science, Scopus, PubMed, Ovid, and Google Scholar) was conducted for all relevant studies published up until May 29, 2023. Only in-vitro studies comparing the adherence of Candida albicans to the digital and conventional acrylic resins were included. The quantitative analyses were performed using RevMan v5.3 software. RESULTS: Fourteen studies were included, 11 of which were meta-analyzed based on Colony Forming Unit (CFU) and Optical Density (OD) outcome measures. The pooled data revealed significantly lower candida colonization on the milled digitally-fabricated compared to the heat-polymerized conventionally-fabricated acrylic resin materials (MD = - 0.36; 95%CI = - 0.69, - 0.03; P = 0.03 and MD = - 0.04; 95%CI = - 0.06, - 0.01; P = 0.0008; as measured by CFU and OD respectively). However, no differences were found in the adhesion of Candida albicans between the 3D-printed digitally-fabricated compared to the heat-polymerized conventionally-fabricated acrylic resin materials (CFU: P = 0.11, and OD: P = 0.20). CONCLUSION: The available evidence suggests that candida is less likely to adhere to the milled digitally-fabricated acrylic resins compared to the conventional ones.


Assuntos
Resinas Acrílicas , Candida albicans , Candida albicans/fisiologia , Bases de Dados Factuais
6.
J Oral Sci ; 66(2): 120-124, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38494704

RESUMO

PURPOSE: To evaluate the flexural properties of repaired poly(methylmethacrylate) (PMMA) denture base materials for computer-aided design/computer-aided manufacturing (CAD-CAM) and to compare them with heat-activated polymerized PMMA. METHODS: A total of 288 specimens (65 × 10 × 2.5 mm) were prepared using both CAD-CAM and conventional blocks and repaired using autopolymerizing and visible-light polymerizing (VLC) materials. Microwave energy, water storage and hydroflask polymerization were applied as additional post-polymerization cycles after the repair process. The flexural strength (FS) of the specimens was evaluated using the three-point bending test. Data were evaluated statistically using 2-way ANOVA followed by Bonferroni's correction to determine the significance of differences between the groups (P ≤ 0.05). RESULTS: The FS of the denture base materials for CAD-CAM was significantly higher than that for the heat-activated group (P ≤ 0.05). The FS was significantly highest when microwave energy was used for the post-polymerization cycle. The FS values for all groups repaired with VLC resin were significantly lower than for the autopolymerization group (P ≤ 0.05). CONCLUSION: The flexural properties of denture base materials for CAD-CAM repaired using autopolymerizing acrylic resins can recover by 50-70%. Additional post-polymerization cycles for autopolymerizing repair resin can be suggested to improve the clinical service properties of repaired dentures.


Assuntos
Materiais Dentários , Resistência à Flexão , Polimetil Metacrilato , Bases de Dentadura , Teste de Materiais , Resinas Acrílicas , Desenho Assistido por Computador , Reparação em Dentadura , Propriedades de Superfície
7.
Polymers (Basel) ; 16(3)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38337311

RESUMO

The main goal of this work was an improvement in the mechanical and electrical properties of acrylic resin-based nanocomposites filled with chemically modified carbon nanotubes. For this purpose, the surface functionalization of multi-walled carbon nanotubes (MWCNTs) was carried out by means of aryl groups grafting via the diazotization reaction with selected aniline derivatives, and then nanocomposites based on ELIUM® resin were fabricated. FT-IR analysis confirmed the effectiveness of the carried-out chemical surface modification of MWCNTs as new bands on FT-IR spectra appeared in the measurements. TEM observations showed that carbon nanotube fragmentation did not occur during the modifications. According to the results from Raman spectroscopy, the least defective carbon nanotube structure was obtained for aniline modification. Transmission light microscopy analysis showed that the neat MWCNTs agglomerate strongly, while the proposed modifications improved their dispersion significantly. Viscosity tests confirmed, that as the nanofiller concentration increases, the viscosity of the mixture increases. The mixture with the highest dispersion of nanoparticles exhibited the most viscous behaviour. Finally, an enhancement in impact resistance and electrical conductivity was obtained for nanocomposites containing modified MWCNTs.

8.
Polymers (Basel) ; 16(4)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38399864

RESUMO

Additive manufacturing (AM), also known as three-dimensional printing (3DP), has been widely applied to various fields and industries, including automotive, healthcare, and rapid prototyping. This study evaluates the effects of 3DP on textile properties. The usability of a textile and its durability are determined by its strength, washability, colorfastness to light, and abrasion resistance, among other traits, which may be impacted by the application of 3DP on the fabric's surface. This study examines the application of photosensitive acrylic resin on two fabric substrates: 100% cotton and 100% polyester white woven fabrics made of yarns with staple fibers. A simple alphanumeric text was translated into braille and the braille dots were 3D printed onto both fabrics. The color of the printed photosensitive acrylic resin was black, and it was an equal mixture of VeroCyanV, VeroYellowV, and VeroMagentaV. The 3D-printed design was the same on both fabrics and was composed of braille dots with a domed top. Both of the 3DP fabrics passed the colorfastness to washing test with no transfer or color change, but 3D prints on both fabrics showed significant color change during the colorfastness to light test. The tensile strength tests indicated an overall reduction in strength and elongation when the fabrics had 3DP on their surface. An abrasion resistance test revealed that the resin had a stronger adhesion to the cotton than to the polyester, but both resins were removed from the fabric with the abrader. These findings suggest that while 3DP on textiles offers unique possibilities for customization and design, mechanical properties and color stability trade-offs need to be considered. Further evaluation of textiles and 3D prints of textiles and their performance in areas such as colorfastness and durability are warranted to harness the full potential of this technology in the fashion and textile industry.

9.
Clin Exp Dent Res ; 10(1): e828, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38345482

RESUMO

BACKGROUND: The second rule of the 4Rs concept (Reduce, Reuse, Recycle, and Recover) was applied in this study using recycled acrylic resin to improve the hardness and study the effect of aging on the hardness of heat cured denture base resins. METHOD: Forty heat-cured acrylic resin samples were prepared and divided into control and modified groups. The hardness was tested using a type D durometer hardness tester for evaluating the effect of the thermal aging process on the hardness in the control and modified groups. The samples were either subjected to thermal aging (the specimens thermo-cycled 10 cycles per day between 55°C and 5°C with a 30-s dwell time) or were not. RESULTS: The mean difference in hardness between specimens with and without aging in the modified group increased with increasing concentrations of incorporated recycled acrylic resin. Independent samples t test revealed that the hardness values of modified groups with aging were significantly higher than in those without aging (p ≤ 0.05). ANOVA revealed that the modified group revealed a significant increase in hardness than that of the control group (p ≤ 0.05). CONCLUSIONS: Recycling and reuse of acrylic resins improved the hardness of denture base resins. The aging period significantly affected the hardness values of the control and modified groups.


Assuntos
Resinas Acrílicas , Temperatura Alta , Dureza , Bases de Dentadura , Teste de Materiais
10.
BMC Oral Health ; 24(1): 151, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38297290

RESUMO

BACKGROUND: Poly-methyl methacrylate (PMMA) is a type of polymer mostly used to make denture bases. Self-cured acrylic resin (PMMA) can be used to repair a fractured acrylic denture base; however, even after repair, this area remains vulnerable. Carbon nanotubes (CNTs) could be used as a filler for polymer reinforcement. Furthermore, silver nanoparticles are efficient agents for the prevention of dental biofilm and improving their mechanical properties. The doping of CNTs with silver nanoparticles may lead to a synergistic interaction that is predicted to enhance the mechanical characteristics of the fillers. OBJECTIVES: The aim of the study was to assess the influnce of manual incorporation of 0.5% weight percent (%wt.) of silver doped carbon nanotubes (Ag-doped CNTs) into commercial self-cured PMMA on its flexural strength, impact strength, and surface microhardness. METHODS: In this investigation, a total of 60 specimens comprised of acrylic resin were employed. They are divided into two main groups: (a) the control group, which was made by using liquid monomer and commercial self-cured PMMA powder; and (b) the modified group, prepared by hand mixing the purchased silver-doped CNTs powder (0.5% wt.) to self-cured PMMA powder (99.5%wt.), and then the blended powder was incorporated into the liquid monomer. Flexural strength, flexural modulus, impact strength, and surface microhardness were evaluated. Independent sample t-tests were used to statistically analyze the data and compare the mean values of flexural strength, flexural modulus, impact strength, and surface microhardness (p-value ≤ 0.05). RESULTS: The flexural strength of the modified groups with Ag-doped CNTs (132.4 MPa) was significantly greater than that of the unmodified (control) groups (63.2 MPa). Moreover, the flexural modulus of the modified groups with Ag-doped CNTs (3.067 GPa) was significantly greater than that of the control groups (1.47 GPa). Furthermore, the impact strength of the modified groups with Ag-doped CNTs (11.2 kJ/mm2) was significantly greater than that of the control groups (2.3 kJ/mm2). Furthermore, the microhardness of the modified groups with Ag-doped CNTs (29.7 VHN) was significantly greater than that of the control groups (16.4 VHN), (p-value = 0.0001). CONCLUSION: The incorporation of 0.5% wt. silver doped CNTs fillers to the self-cured acrylic resin enhanced its flexural strength, flexural modulus, impact strength, and surface microhardness.


Assuntos
Nanopartículas Metálicas , Nanotubos de Carbono , Humanos , Resinas Acrílicas , Polimetil Metacrilato , Resistência à Flexão , Prata , Pós , Teste de Materiais , Bases de Dentadura , Polímeros , Propriedades de Superfície
11.
Cureus ; 15(11): e48189, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38054115

RESUMO

Background One of the frequent aesthetic issues patients confront is the loss of colour and lifeless appearance of the dentures of the base materials of their dentures after regular use. This leads to a lack of motivation to use the denture regularly. Due to the drawbacks of conventional PMMA, polyether ether ketone (PEEK) and newer polymethyl methacrylate (PMMA)-based materials have now started being used in cast partial denture frameworks due to their superior physical and biological properties. The lack of long-lasting colour is one of the main reasons for the repeat of dental prostheses. Hence, the need for the study is to help clinicians decide which would be the most suitable denture base material to be used based on colour stability. Aim To assess and compare the colour stability of PEEK, polyan, and biodentaplast denture base materials (DBMs) upon staining with distilled water, tea, coffee, and turmeric solutions after one day, seven days, and 30 days. Methods A total of 20 cuboidal specimens were constructed and immersed in distilled water, tea, coffee, and turmeric (five specimens of each material in each solution, a total of 60 specimens): Group 1: PEEK, Group 2: polyan, Group 3: biodentaplast. All specimens were subjected to colour measurements before exposure to beverage solutions, after 24 hours, on the seventh day and 30th day with a colour reflectance spectrophotometer with computer software. A one-way ANOVA test followed by post hoc Tukey's honestly significant difference (HSD) was performed for comparison of colour stability between the DBMs, revealing a significant difference between PEEK and polyan and PEEK and biodentaplast. Polyan showed the highest delta E values, followed by biodentaplast and PEEK. A two-way ANOVA test, followed by Tukey's HSD post hoc, was done to compare the staining ability of various staining solutions. Turmeric had the highest delta E values, followed by coffee, tea, and distilled water. Data were assessed using Statistical Product and Service Solutions (SPSS, version 23) (IBM SPSS Statistics for Windows, Armonk, NY) software. Results The highest mean delta E value at T1 was seen in biodentaplast immersed in turmeric (12.3900+/-0.442), and the least value at T1 was obtained for PEEK immersed in distilled water (0.4460+/-0.036). The highest mean delta E value at T2 was seen in polyan immersed in turmeric (13.0160+/-0.28962), and the least value at T2 was obtained for PEEK immersed in distilled water (0.5860+/-0.051). At T3, the highest mean delta E value was seen in polyan immersed in turmeric (16.8600+/-0.49845), and the least value at T3 was obtained for PEEK immersed in distilled water (0.700+/-0.037). Conclusion PEEK had the highest colour stability when compared with polyan and biodentaplast.

12.
BMC Oral Health ; 23(1): 844, 2023 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-37940890

RESUMO

BACKGROUND: This study aimed to determine the relative positioning accuracy of multiple implants utilizing four distinct types of splinting materials. METHODS: The purpose of this in-vitro study was to compare the precision of four splinting materials in an open tray impression technique in multiple implant situations. Based on the material used for splinting, four groups were made (n = 40)- Group A: Conventional Method, Group B: Prefabricated Pattern Resin Framework, Group C: Prefabricated Metal Framework, Group D: Light Cured Pattern Resin, these groups were compared with the master model. A heat-cured clear acrylic resin and a master model were constructed. A pilot milling machine drill was used to drill four parallel holes in the anterior and premolar regions, which were later labeled as A, B, C, and D positions from right to left. Then, sequential drilling was carried out, and four 3.75­mm diameter and 13-mm long ADIN implant analogs with internal hex were placed in the acrylic model using a surveyor for proper orientation. The impression posts were then manually screwed to the implant analogs using an open tray, and they were secured to the implants using 10 mm flat head guide pins with a 15 N.cm torque. 10 Open tray polyether impressions were made, and casts were poured. Each splinting method's distortion values were measured using a coordinate measuring machine capable of recordings in the X-, Y-, and Z-axes. Comparison of mean distances for X1, X2, and X3 was made using the Kruskal-Wallis test, and Pairwise comparison was done using Post Hoc Tukey's Test. RESULTS: The differences between the groups were significant when assessing the distances X1, X2, and X3 (p < 0.05). The comparison of deviations between the groups revealed a statistically significant difference (p < 0.05) for the deviation distance X3 but not for the deviation distances X1 and X2. For distance Y1, the difference between the groups was statistically significant (p0.05), but it was not significant for distances Y2 and Y3. A statistically significant difference was seen in the comparison between the groups (p < 0.05) for the deviation distances Y1, Y2, and Y3. The results were statistically significant for the distance Z1 comparisons, namely, control vs. Group A (p = 0.012), control vs. Group B (p = 0.049), control vs. Group C (p = 0.048), and control vs. Group D (p = 0.021), and for distance Z3 comparison for control vs. Group A (p = 0.033). The results were statistically insignificant for the distance Z2 comparisons (p > 0.05). CONCLUSIONS: All splinting materials produced master casts with measurements in close proximity to the reference model. However, prefabricated pattern resin bars splinting showed the highest accuracy among the studied techniques. The most recent splinting techniques using prefabricated metal framework and light-cure pattern resin showed similar accuracy.


Assuntos
Implantes Dentários , Humanos , Técnica de Moldagem Odontológica , Materiais para Moldagem Odontológica , Modelos Dentários , Resinas Acrílicas
13.
Antibiotics (Basel) ; 12(11)2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37998832

RESUMO

To assess the effect of hygiene protocols and time on the physical-mechanical properties and colony-forming units (CFU) of Candida albicans, Staphylococcus aureus, and Streptococcus mutans on 3D-printed denture resins (SmartPrint and Yller) with extrinsic pigmentation compared to conventional resin (CR). The protocols were evaluated: brushing (B), brushing and immersion in water (W), 0.25% sodium hypochlorite (SH), and 0.15% triclosan (T), simulating 0, 1, 3, and 5 years. The data were analyzed by ANOVA with repeated measurements, ANOVA (Three-way) and Tukey's post-test, generalized linear model with Bonferroni adjustment, and ANOVA (Two-way) and Tukey's post-test (α = 0.05). The protocols influenced color (p = 0.036) and Knoop hardness (p < 0.001). Surface roughness was influenced by protocols/resin (p < 0.001) and time/resin (p = 0.001), and flexural strength by time/protocols (p = 0.014). C. albicans showed interactions with all factors (p = 0.033). Staphylococcus aureus was affected by protocols (p < 0.001). Streptococcus mutans exhibited no count for SH and T (p < 0.001). Yller resin showed more color changes. The 3D-printed resins displayed lower microhardness, increased roughness, and decreased flexural strength compared to CR with all protocols in a simulated period of 5 years. The indication of printed resins should be restricted to less than 3 years.

14.
Biomater Investig Dent ; 10(1): 2268670, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38027422

RESUMO

To assess the influence of dentifrices with different abrasiveness levels on the properties of dental reconstructive materials. Forty-eight cylinders were obtained from four polymeric materials, being two CAD/CAM acrylic resins (Ivotion-Dent and Ivotion-Base), one injected acrylic resin (IvoBase-Hydrid) and one light-cured resin composite (Empress Direct). Specimens were allocated to four subgroups for toothbrushing simulation according to the dentifrice relative dentin abrasivity (RDA) and silica content: (i) RDA 0 = 0%; (ii) RDA 50 = 3%; (iii) RDA 100 = 10%; and (iv) RDA 120 = 25%. Specimens were then subjected to toothbrushing. Surface analyses [surface roughness Ra (SR) and scanning electron microscopy (SEM)] along with hardness and optical properties [translucency parameter (TP) and contrast ratio (CR)] were evaluated before and after toothbrushing. Statistical analyses were performed using ANOVA and Tukey test. A significant increase in SR was observed after toothbrushing with higher RDA toothpastes for Ivotion-Dent (100 and 120) and IvoBase-Hybrid (120). Ivotion-Base and Empress Direct presented no significant differences in SR when analyzed as a function of timepoint and RDA levels. Hardness was not influenced by toothbrushing with different RDA dentifrices, except for Empress Direct with RDA 0 toothpaste, where a decrease in the hardness was observed. TP of Ivotion-Dent and Empress Direct significantly decreased after toothbrushing with higher RDA dentifrices and CR of Ivotion-Dent, Empress Direct and IvoBase-Hybrid significantly increased with higher RDA dentifrices. The levels of dentifrice abrasiveness affected differently the SR, hardness and optical properties of polymeric reconstructive materials after toothbrushing.

15.
Cureus ; 15(11): e48883, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38024043

RESUMO

The aim of the study was to evaluate the effect of airborne particle abrasion (using different sizes of alumina particles) on the shear bond strength (SBS) between cast and milled titanium metal frameworks and auto-polymerizing acrylic repair resin. Forty flat cylindrical titanium disks were divided into two main divisions: cast and milled titanium. The two divisions were further subdivided into four groups based on metal surface treatment. Three particle sizes of aluminum oxide air abrasive powders (50µm, 110µm, and 250µm) were used for metal surface treatment by airborne particle abrasion. One group was the control group with no surface treatment. Auto-polymerizing acrylic repair resin was applied to all titanium disks. The specimens were subjected to SBS testing using a universal testing machine (Instron Corporation, Norwood, Massachusetts, United States). Surface evaluation was performed using a scanning electron microscope. One-way ANOVA was used for statistical analysis. The results showed a significant increase in SBS after airborne particle abrasion of both milled and cast titanium groups (p<0.001). The SBS was directly proportional to the size of the aluminum oxide particles. The milled titanium group showed higher SBS values than the cast group when the surface was not treated with alumina particles (p < 0.001) and when the surface was treated with the smaller particle sizes of 50 µm, whereas the cast group demonstrated higher SBS values than the milled group (p < 0.01) when the particle size was increased to 110 µm and 250 µm. It could be concluded that SBS between titanium metal frameworks and auto-polymerizing repair acrylic resin was directly related to the size of the alumina airborne particle abrasives. The fabrication method of the titanium framework also influenced the SBS as the untreated milled frameworks demonstrated favorable SBS values compared to the untreated cast frameworks.

16.
Front Chem ; 11: 1260533, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37789965

RESUMO

Four distinct fluorescence complexes, the fluorescent complex-1 (FC-1), fluorescent complex-2 (FC-2), fluorescent complex third (FC-3) and fluorescent complex fourth (FC-4), were created using isorhamnetin and Coomassie brilliant blue G250 as raw materials. The issue of isorhamnetin's low solubility has been resolved, and isorhamnetin-coomassie brilliant blue G250 now has better biocompatibility. Four different forms of fluorescence compounds' ultraviolet absorption spectra were identified. It was discovered that FC-2, FC-3, and FC-4, respectively, had double peaks at 483-620 nm. FC-4 had the highest ultraviolet absorption intensity, whereas FC-1 exhibited the most consistent and longest wavelength of ultraviolet absorption. Transmission electron microscopy revealed that the acrylic resin evenly disseminated the Coomassie brilliant blue G250-isorhamnetin complex in an amorphous flocculent form. Human prostate cancer cells (PC3) and human cervical cancer cells (HeLa) were investigated in the (Cell Counting Kit-8) CCK8 experiment under 10 different concentration circumstances, and the proliferation impact was 64.30% and 68.06%, respectively. Shown the complex's strong anti-tumor properties and minimal cytotoxicity. Through in vitro imaging of tumor cells, it was found that FC-1's fluorescent complex has high selectivity and can accurately infiltrate tumor cells, proving that it is biocompatible. The design not only addresses the issue of isorhamnein-Coomassie Bright Blue G250's bioavailability, but it also has an effective visual fluorescence targeting effect.

17.
Dent Mater J ; 42(6): 791-799, 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-37793826

RESUMO

Incorporating zinc oxide (ZnO) nanoparticles as antibacterial fillers in heat-cured acrylic resin could decrease mucin and Streptococcus mutans (S. mutans) adhesion, reducing the incidence of dental caries in the baseplates of orthodontic patients. Here, ZnO nanoparticles were modified using 3-(trimethoxysilyl)propyl methacrylate with various concentrations, added to acrylic resin powder, homogenized, mixed with acrylic resin liquid, and processed. The composite systems interfered well with mucin and S. mutans adhesion. The lowest mean of the amount of mucin adhered was on heat-cured acrylic resin with 7.5% ZnO nanoparticles, with a standard deviation of 18.07±0.80 mg/mL. The ZnO nanoparticles with a concentration of 7.5% showed an 87.09±0.88% S. mutans adhesion in control groups with no additives. These composite systems were proven to have better physicochemical characteristics and antibacterial abilities. Combining ZnO nanoparticles with heat-cured acrylic resin has great potential for self-cleaning baseplates of orthodontic patients in the future.


Assuntos
Cárie Dentária , Nanopartículas , Óxido de Zinco , Humanos , Resinas Acrílicas/farmacologia , Óxido de Zinco/farmacologia , Streptococcus mutans , Resinas Compostas/farmacologia , Mucinas/farmacologia , Temperatura Alta , Antibacterianos/farmacologia
18.
Int J Biol Macromol ; 253(Pt 2): 126743, 2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-37689290

RESUMO

Cellulose nanocrystals (CNCs) are green reinforcing materials, and their potential has been evaluated in the preparation of waterborne UV-curable resin composites with high-performance. Herein, we present a novel and scalable approach for preparing surface-modified CNCs with acrylic-based polymers to strengthen the compatibility and interaction between CNCs and UV-curable resins. Using tert-butyl acrylate as the monomer, the nanocellulose grafted copolymer CNC-g-PtBA was successfully synthesized via atom transfer radical polymerization (ATRP) in the presence of a macromolecular initiator. Then, the CNC-g-PtBA is blended into the acrylic resin as a nanofiller to prepare the UV-curable nanocomposite. The results indicated that the contact angle of the CNCs increased from 38.7° to approximately 74.8°, and their thermal stability was significantly improved after graft modification. This contributed to the effective alleviation of the agglomeration phenomenon of nanocomposites due to the high hydrophilicity of pure CNCs. Notably, not only was the UV curing efficiency of the nanocomposites greatly increased but the mechanical properties were also further enhanced. Specifically, with the addition of 0.5 wt% CNC-g-PtBA, the curing time of the nanocomposite was shortened from >30 mins down to approximately 6 mins, and the bending strength was increased from 10 MPa for the original resin and 5 MPa for the addition of pure CNCs to 14.3 MPa, and the bending modulus was also greatly increased (up to approximately 730 MPa). Compared to pure CNCs, they are compatible with the resin, exhibiting high mechanical strength and flexibility, and have virtually no effect on the light transmission of the nanocomposites. Additionally, dielectric analysis (DEA) was used to monitor the dielectric constant and conductivity of the UV-curable nanocomposites in real time to further characterize their curing kinetics. The permittivity of these nanocomposites increased by 125 % compared to pristine resin, which shows potential for applications in high dielectric composites or for improving electrical conductivity. This work provides a feasible method for preparing UV-curable nanocomposites with high curing efficiency and permittivity, realizing a wider application of this high-performance nanocomposite.


Assuntos
Nanocompostos , Nanopartículas , Polimerização , Polímeros , Nanopartículas/química , Nanocompostos/química
19.
J Family Reprod Health ; 17(1): 54-57, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37538226

RESUMO

Objective: Vaginal agenesis or atresia in females suffering from MRKH syndrome is more common and management involves both surgical and non-surgical approaches. Use of prefabricated stents to maintain the patency of the canal may not fit appropriately during the initial surgical phase and are not economical. This case report discusses a series of modifications in a custom-made vaginal dilator to improve the retention for expansion after surgical management of MRKH syndrome. Case report: A 28-year-old female diagnosed with MRKH syndrome with characteristic Mullerian agenesis was referred for customised vaginal stent. Customised surgical stent was fabricated with loops for orientation and retention, which was later modified into interim expansion and passive stent. Conclusion: The customisation of the vaginal stent, provision of a retentive loop that positioned the stent in the proper orientation, and gradual increase in the size of the stent, ensured dilatation in a patient with vaginal agenesis.

20.
Cureus ; 15(7): e41989, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37593259

RESUMO

Fabrication of prosthetic fingers is more of an art than a science. The prosthetic finger must match the missing fingers or digits to such an extent to have a natural aesthetic look for the patient. This would build up the patient's confidence and prevent unwanted attraction by others. A patient, 47 years old, reported the loss of the middle finger of the right hand. The loss of the right middle finger was till the first phalanx, and it was distorted till the second phalanx. The patient wanted to have a natural look at his hand. Alginate impressions of the patient's amputated finger and the donor's relevant matching fingertip were made. A waxed prosthesis pattern was fabricated with the donor's fingertip. A wax trial was done in the patient, and was flasked. A heat cure acrylic was intrinsically painted with acrylic paint color to match the adjacent finger's skin tone, followed by packing these in the dewaxed mold, processed, trimmed, finished, and polished. This case report describes a method of obtaining or enhancing retention of the prosthetic finger by adopting a customized finger ring on the master cast and also customizing the prosthesis in the clinical rest position to have the aesthetic appearance in the resting condition of the palms and fingers. This method is cheaper and very easy to be adopted for affected people.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...